橫河ADV151-P00數(shù)字量輸入模塊
Digital Input Modules
The Digital Input Modules receive 32-channel or 64-channel 24 V DC ON/OFF signals. The ADV151 and ADV161 can be used in dual redundant con?guration.
Item | Speci?cations | ||
Model | ADV151-P/ADV151-E (*1) | ADV157 | ADV161 |
Number of input channels | 32 | 32 | 64 |
Rated input voltage (*2) | 24 V DC (sink/source) | 24 V DC (sink/source) | 24 V DC (sink/source) |
Input ON voltage | 18 to 26.4 V DC | 18 to 26.4 V DC | 20 to 26.4 V DC |
Input OFF voltage | 5.0 V DC or less | 5.0 V DC or less | 5.0 V DC or less |
Input current (at rated input voltage) | 4.1 mA±20 % / channel | 4.1 mA±20 % / channel | 2.5 mA±20 % / channel |
Maximum allowable input voltage | 30.0 V DC | 30.0 V DC | 30.0 V DC |
Withstanding voltage | Between input signal and system: 2 kV AC, For 1 minute Between commons: 500 V AC, For 1 minute, common every 16-channel (*3) | ||
Functions Status input
Pushbutton input |
Function for detecting ON/OFF status Function for counting the pushbutton edges |
Function for detecting ON/OFF status — |
Function for detecting ON/OFF status Function for counting the pushbutton edges |
Input response time | 8 ms or less (for status input) | ||
Minimum ON detection time | 20 ms (for pushbutton input) | ||
Maximum ON/OFF cycle | 25 Hz (for pushbutton input) | ||
Maximum current consumption | 500 mA (5 V DC) | 350 mA (5 V DC) | 550 mA (5 V DC) |
Weight | 0.3 kg | 0.4 kg | 0.3 kg |
External connection | Pressure clamp terminal, Dedicated cable (AKB331), MIL connector cable |
Pressure clamp terminal |
Dedicated cable (AKB337), MIL connector cable |
*1: Only ADV151-P is allowed to be installed in the remote node. ADV151-E is not allowed to be installed in the remote node.
*2: ADV151, ADV157 and ADV161 are common every 16-channel. All voltage input signals to be connected (24 V DC) must be in the same polarity.
*3: The withstanding voltage for using a dedicated cable is 500 V AC (between input signal and system).
The withstanding voltage for using MIL connector cable depends on the electrical speci?cations of its cable.
ADV141-E63/D5A00 ADV142-E63/D5A00 ADV157-S61/D5A00 ADV151-E63/D5A00
ADV141-PE3/D5A00 ADV142-PE3/D5A00 ADV157-PE1/D5A00 ADV151-PE3/D5A00
ADV141-EF3/D5A00 ADV142-EF3/D5A00 ADV157-SF1/D5A00 ADV151-EF3/D5A00
ADV141-P03/D5A00 ADV142-P03/D5A00 ADV157-P01/D5A00 ADV151-P03/D5A00
ADV141-E03/D5A00 ADV142-E03/D5A00 ADV157-S01/D5A00 ADV151-E03/D5A00
ADV141-P13/D5A00 ADV142-P13/D5A00 ADV157-P11/D5A00 ADV151-P13/D5A00
ADV141-E13/D5A00 ADV142-E13/D5A00 ADV157-S11/D5A00 ADV151-E13/D5A00
本技術規(guī)范書中涉及的所有規(guī)范、標準或材料規(guī)格(包括一切有效的補充或附錄)均為版本,即以用戶發(fā)出本DCS訂單之日作為采用版本的截止日期。當參照的規(guī)范和標準與本規(guī)范書存在明顯沖突時,YOKOGAWA橫河應向用戶指出沖突之處并取得用戶的書面意見。引用的規(guī)范和標準:
(1)美國防火協(xié)會(NFPA)
ANSI/NFPA 70 美國國家防火協(xié)會電氣規(guī)范
ANSI/NFPA 8504 常壓循環(huán)流化床鍋爐運行標準
(2)美國電氣和電子工程師協(xié)會(IEEE)
ANSI/IEEE 472 沖擊電壓承受能力導則(SWC)
ANSI/IEEE 488 可編程儀表的數(shù)字接口
(3)美國電子工業(yè)協(xié)會(EIA)
EIA RS-232-C 資料終端設備與使用串行二進制數(shù)據(jù)進行
資料交換的數(shù)據(jù)通訊設備之間的接口
EIA RS-485 資料終端設備與使用串行二進制數(shù)據(jù)進行
資料交換的數(shù)據(jù)通訊設備之間的接口
(4)美國儀器學會(ISA)
ISA IPTS 90 熱電偶換算表
ISA RP55.1 數(shù)字處理計算機硬件測試
(5)美國科學儀器制造商協(xié)會(SAMA)
SAMA PMC 22.1 儀表和控制系統(tǒng)功能圖表示法
SAMA PMC 31.1 過程測量和控制儀表試驗和評估的一般方法
SAMA PMC 33.1 過程控制儀表的電磁感應特性
(6)美國電氣制造商協(xié)會(NEMA)
ANSI/NEMA ICS4 工業(yè)控制設備和系統(tǒng)的端子排
ANSI/NEMA ICS6 工業(yè)控制設備和系統(tǒng)外殼
(7)美國機械工程師協(xié)會
ANSI/ASME TDP-1-1985 電站蒸汽輪機防進水保護措施
(8)美國保險商實驗室(UL)
UL 1418 電視用陰極射線管的防內(nèi)爆
UL 44 橡膠導線、電纜的安全標準
(9)IEC標準
IEC 60068-1 環(huán)境試驗:總論和導則(88)
IEC 60073 用顏色指示設備的規(guī)則(96)
IEC 60079 用于易爆場所的電氣設備
IEC 60331 電纜阻燃特性(70)
IEC 60332 燃燒情況下的電纜試驗(93)
IEC 60348 電氣測量設備的安全要求(78)
IEC 60529 外殼防護等級(IP碼)(EQV)
IEC 60801-1 工業(yè)過程測量和控制裝置的電磁兼容性
第1部分:總論(EQV)
IEC 60801-2 工業(yè)過程測量和控制裝置的電磁兼容性
第2部分:靜電放電要求(EQV)