      產(chǎn)品簡介

      GSTH-1420GSTH-1100GRTHO-1420GRTHO-1420Pt100GRTHO-1420Pt1000GRTHO-1420N3K室內(nèi)用溫濕度變送器ROOMTEMP

      詳細介紹

       

       

      GSTH-1420 GSTH-1100 GRTHO-1420 GRTHO-1420Pt100 GRTHO-1420Pt1000 GRTHO-1420N3K室內(nèi)用溫濕度變送器 ROOM TEMP./HUMI. TRANSMITTER

       

      ROOM TEMP./HUMI. TRANSMITTER(GSTH-1420)
      "GSTH" Room Temperature Humidity Transmitter is intended for ventilation and air-handling units to detect Room temperature and relative humidity.
      Especially, This unit is very suitable for use in pulp/textile/food warehouse, greenhouse, computer room, R&D room, indoor swimming pool, hospital, etc.
      This unit can be used with all system equipments that can receive output signals 4-20mA DC of the detector.
      Relative Humidity
      1) This Transmitter senses relative humidity by chargeable humidity sensing element which varies electrical capacity depending on circumstantial relative humidity.
      2) Electronic sensing circuit varies signal into 4 ~ 20mA DC ( within 0 ~ 99% relative humidity )
      Temperature
      This Transmitter senses temperature by sensing element of PT1000Ω which varies electrical resistance depending on sensing temperature.

      SUPPLY VOLTAGE : 24V AC ± 20%
      FREQUENCY : 50 or 60Hz
      POWER CONSUMPTION : below 1VA
      SENSING RANGE : -10 ~ +70℃ / 0 ~99%RH
      HUMIDITY ELEMENT : Integrated Circuity 
      ACCURACY ( at 20°C ) : at 20~90% Rh, ±3%Rh
      OUTPUT SIGNAL : Pt100(Pt1000Ω) / 4 ~ 20mADC
      SENSING TIME : About 20sec
      AMBIENT TEMPERATURE : 1) On operation : -10 ~ +70℃
      2) On storage & Transportation : -25 ~ +65°C
      AMBIENT HUMIDITY : 1) On operation : below 95%Rh
      WIRING : 2and 3wires, 1.0m㎡
      WEIGHT : 0.06Kg
      HOUSING : plastic case
      PROTECTION CLASS : IP30

      Engineering
      1) In case of control : Preferably install on the wall of building or house and keep away from direct light,
      Select a location approx 1.5M above the floor for the sensor which is representative of the space to be controlled and where it will be readily affected by changing in the general space temperature & humidity level.
      The sensor location should also be reasonably clean and free damp and condensation.
      ROOM TEMP./HUMI. TRANSMITTER(GSTH-1100)
      "GSTH" Room Temperature Humidity Transmitter is intended for ventilation and air-handling units to detect Room temperature and relative humidity.
      Especially, This unit is very suitable for using in pulp/textile/food warehouse, greenhouse, computer room, R&D room, indoor swimming pool, hospital, etc.
      This unit can be used with all system equipments that can receive output signals 0 ~10V DC of the detector.
      Relative Humidity
      1)This Transmitter senses relative humidity by chargeable humidity sensing element
      which varies electrical capacity depending on circumstantial relative humidity.
      2)Electronic sensing circuit varies signal into 0 ~ 10V DC ( within 0 ~ 99% relative humidity )
      Temperature
      This Transmitter senses temperature by sensing element of PT1000Ω which varies electrical resistance depending on sensing temperature.

      SUPPLY VOLTAGE : 24V AC/DC ± 20%
      FREQUENCY : 50 or 60Hz
      POWER CONSUMPTION : below 1VA
      SENSING RANGE : -10 ~ +70℃ / 0 ~ 99% RH
      HUMIDITY ELEMENT : Integrated Circuity
      ACCURACY ( at 20°C ) : at 20~90% Rh, ±3%Rh
      OUTPUT SIGNAL : Pt1000Ω(Pt100Ω) / 0 ~ 10VDC
      SENSING TIME : Apprx 20sec
      AMBIENT TEMPERATURE : 1) On operation : -10 ~ +70℃
      2) On storage & Transportation : -25 ~ +65°C
      AMBIENT HUMIDITY : 1) On Operation : below 95%Rh
      WIRING : 2and 3wires, 1.0m㎡
      WEIGHT : 0.06Kg
      HOUSING : plastic case
      PROTECTION CLASS : IP30

      Select a location approx 1.5M above from the floor.
      The sensor location should also be reasonably clean and free damp and condensation.
      ROOM TEMP./HUMI. TRANSMITTER(GRTHO-1420Pt1000)
      GRTHO" Room Temperature & Humidity Transmitter is intended for control transmitter by sensing relative humidity and temperature of room ventilation and air-handling units. Also can be used interface detect transmitter with sensing value display or auto control system of building
      Pulp/Textile/Food warehouse, greenhouse, computer room, R&D room, Hospital, etc.
      Use as measuring Transmitter : In case of optimistic function system.
      SUPPLY VOLTAGE : DC 15~30V  
      OUTPUT SIGNAL : Temperature / Pt1000Ω, Humidity / 4 ~ 20mA
      SENSING RANGE : Temperature / -10 ~ +70°C , Humidity / 0 ~ 99%RH
      SENSING ELEMENT : Integrated Circuity, PT1000
      TEMPERATURE CO-EFFICIENT : 0.00385 OHMS
      SELF-GENERATING CURRENT : below 2mA ( 0.02 OHM / 0.05 Deg.)
      ACCURACY : at 25°C within ±0.3°C / ±3% RH at 10 ~ 90%RH
      WIRING : 4 Wire
      SENSING TIME : within 1 minute apprx.
      AMBIENT TEMPERATURE
      1) On Operation : -10 ~ +70°C
      2) On Transportation & storage : -15 ~ +50°C
      AMBIENT HUMIDITY
      1) On Operation : below 95%Rh
      PROTECTION CLASS ENCLOSURE : IP30 (EN60529)
      WEIGHT : 0.10 Kg
      Engineering
      In case of control : Preferably install on the wall of house or building, and keep away from direct light.
      1) Installation height : Preferably install in the middle of house, building or heating area.
      and to be installed at least 1.5 meter above from the floor.
      2) Prohibited Location : Window, door, Ventilation hole, upper place of heat source, and Veranda, or beneath the eaves of roof
      3) To prevent any detecting error from convection of warm air, cable wire tube of transmitter should be shielded, and must not be painted.
      ROOM TEMP./HUMI. TRANSMITTER(GRTHO-1420N3K)
      “ GRTHO" Room Temperature & Humidity Transmitter is intended for control transmitter by sensing relative humidity and temperature of room ventilation and air-handling units. Also can be used interface detect transmitter with sensing value display or auto control system of building.
      Pulp/Textile/Food warehouse, greenhouse, computer room, R&D room, Hospital, etc.
      Use as measuring Transmitter : In case of optimistic function system .
      SUPPLY VOLTAGE : 15~30VDC
      OUTPUT SIGNAL : Temperature / NTC 3KΩ, Humidity / 4 ~ 20mA
      SENSING RANGE : Temperature / -10 ~ +70°C , Humidity / 0 ~ 99%RH
      SENSING ELEMENT : Integrated Circuity, NTC Ω
      SELF-GENERATING CURRENT : below 2mA
      ACCURACY : at 20°C within ±3%RH ( humidity )
      WIRING : 4 Wire
      SENSING TIME : within 1 minute apprx.
      AMBIENT TEMPERATURE
      1) On Operation : -10 ~ +70°C
      2) On Transportation & storage : -15 ~ +60°C
      AMBIENT HUMIDITY
      1) On Operation : below 99%Rh
      2) On Transportation & storage : below 95%Rh
      PROTECTION CLASS : IP30 (EN60529)
      WEIGHT : 0.10 Kg
      Engineering
      In case of control : Preferably install on the wall of house or building, and keep away from direct light.
      1) Installation height : Preferably install in the middle of house, building or heating area.
      and to be installed at least 1.5 meter above from the floor.
      2) Prohibited Location : Window, door, Ventilation hole, upper place of heat source, and Veranda, or beneath the eaves of roof
      3) To prevent any detecting error from convection of warm air, cable wire tube of transmitter should be shielded, and must not be painted
      ROOM TEMP./HUMI. TRANSMITTER(GRTHO-1420)
      ROOM TEMP./HUMI. TRANSMITTER(GRTHO-1420Pt100)
      "GRTHO" Room Temperature & Humidity Transmitter is intended for control transmitter by sensing relative humidity and temperature of room ventilation and air-handling units.
      Also can be used interface detect transmitter with sensing value display or auto control system of building.
      Pulp/Textile/Food warehouse, greenhouse, computer room, R&D room, Hospital, etc.
      Use as measuring Transmitter : In case of optimistic function system
      SUPPLY VOLTAGE : DC 15~30V +20%
      OUTPUT SIGNAL : Temperature / Pt100Ω, Humidity / 4 ~ 20mA
      SENSING RANGE : Temperature / -10 ~ +70°C , Humidity / 0 ~ 99%RH
      SENSING ELEMENT : Integrated Circuity, PT100
      TEMPERATURE CO-EFFICIENT : 0.00385 OHMS
      SELF-GENERATING CURRENT : below 2mA
      ACCURACY : at 25°C within ±0.3°C / ±3% RH at 10-90%RH
      WIRING : 4 Wire
      SENSING TIME : within 1 minute apprx
      AMBIENT TEMPERATURE
      1) On Operation : -10 ~ +70°C
      2) On Transportation & storage : -15 ~ +50°C
      AMBIENT HUMIDITY
      1) On Operation : below 95%Rh
      PROTECTION CLASS : IP30 (EN60529)
      WEIGHT : 0.10 Kg
      Engineering
      1) In case of control : Preferably install on the wall of house or building, and keep away from direct light.
      1) Installation height : Preferably install in the middle of house, building or heating area.
      and to be installed at least 1.5 meter above from the floor.
      2) Prohibited Location : Window, door, Ventilation hole, upper place of heat source, and Veranda, or beneath the eaves of roof
      3) To prevent any detecting error from convection of warm air, cable wire tube of transmitter should be shielded, and must not be painted.

      “ GOTHO “ Outside Air temperature & Humidity Transmitter is intended for controlling Sensor by detecting relative humidity and temperature of outside air for ventilation and air-handling units. This unit can also be used as Interface detector used with display
      of sensing value or Auto control system of building

      Pulp/Textile warehouse, Greenhouse, Computer room, R&D room, Hospital, etc.
      Use measuring detector : In case of Optimistic function system

      SUPPLY VOLTAGE

      : 15 ~ 30V DC

      OUTPUT SIGNAL

      : 4 ~ 20 mA

      SENSING RANGE

      : Temperature /-20 ~ +50°C,
        Humidity / 0 ~ 99%RH

      SENSING ELEMENT

      : Pt 1000Ω / Integrated Circuity

      SELF-GENERATING CURRENT

      : below 2mA ( 0.02 OHM / 0.05 Deg.)

      ACCURACY

      : at 20°C within ±0.3°C,
        at 10 ~ 90%RH, ±3%RH

      WIRING

      : 4 Wire

      SENSING TIME

      : 1 minute apprx.

      AMBIENT TEMPERATURE

      : 1) On Operation : -30 ~ +70°C
        2) On Transportation & Storage : -20 ~ +50°C

      AMBIENT HUMIDITY

      : 1) On Operation : below 99%Rh
        2) On Transportation & Storage : below 95%Rh

      PROTECTION CLASS

      : IP30 (EN60529)

      WEIGHT

      : 0.10 Kg

      Engineering
      1) In case of control : Preferably install on the wall of building or house and keep away from direct light.

      1) Installation height ; Preferably install in the middle of house, building or heating area, and to be installed at least 1.5 meter above from the floor.
      2) Prohibited Location ; Window, door, Ventilating hole, upper place of heat source, and Veranda or beneath the eaves of roof.
      3) To prevent any detecting errors from convection of warm air, cable wire tube of transmitter should be shielded and must not be painted
      ROOM TEMP./HUMI. TRANSMITTER(GRTHO-1420N3K)
      “ GRTHO" Room Temperature & Humidity Transmitter is intended for control transmitter by sensing relative humidity and temperature of room ventilation and air-handling units. Also can be used interface detect transmitter with sensing value display or auto control system of building.
      Pulp/Textile/Food warehouse, greenhouse, computer room, R&D room, Hospital, etc.
      Use as measuring Transmitter : In case of optimistic function system .
      SUPPLY VOLTAGE : 15~30VDC
      OUTPUT SIGNAL : Temperature / NTC 3KΩ, Humidity / 4 ~ 20mA
      SENSING RANGE : Temperature / -10 ~ +70°C , Humidity / 0 ~ 99%RH
      SENSING ELEMENT : Integrated Circuity, NTC Ω
      SELF-GENERATING CURRENT : below 2mA
      ACCURACY : at 20°C within ±3%RH ( humidity )
      WIRING : 4 Wire
      SENSING TIME : within 1 minute apprx.
      AMBIENT TEMPERATURE
      1) On Operation : -10 ~ +70°C
      2) On Transportation & storage : -15 ~ +60°C
      AMBIENT HUMIDITY
      1) On Operation : below 99%Rh
      2) On Transportation & storage : below 95%Rh
      PROTECTION CLASS : IP30 (EN60529)
      WEIGHT : 0.10 Kg
      Engineering
      In case of control : Preferably install on the wall of house or building, and keep away from direct light.
      1) Installation height : Preferably install in the middle of house, building or heating area.
      and to be installed at least 1.5 meter above from the floor.
      2) Prohibited Location : Window, door, Ventilation hole, upper place of heat source, and Veranda, or beneath the eaves of roof
      3) To prevent any detecting error from convection of warm air, cable wire tube of transmitter should be shielded, and must not be painted

      關(guān)鍵詞:溫濕度變送器

      感興趣的產(chǎn)品PRODUCTS YOU ARE INTERESTED IN

      17

      面議

      11

      面議

      0955405

      面議

      ZCZH系列2

      面議

      19

      面議

      124

      面議

      YMF-50

      面議

      134

      面議

      智能制造網(wǎng) 設(shè)計制作,未經(jīng)允許翻錄必究 .? ? ? Copyright(C)?2021 http://www.towegas.com,All rights reserved.

      以上信息由企業(yè)自行提供,信息內(nèi)容的真實性、準確性和合法性由相關(guān)企業(yè)負責,智能制造網(wǎng)對此不承擔任何保證責任。 溫馨提示:為規(guī)避購買風險,建議您在購買產(chǎn)品前務(wù)必確認供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。

      會員登錄

      ×

      請輸入賬號

      請輸入密碼

      =

      請輸驗證碼

      收藏該商鋪

      登錄 后再收藏

      提示

      您的留言已提交成功!我們將在第一時間回復(fù)您~