      西門(mén)子972-0BB41-0XA0 西門(mén)子972-0BB41-0XA0 

      possible to connect the following bus connectors to the MPI interface: With socket: 6ES7 972-0BB42-0XA0 Without socket: 6ES7 972-0BA42-0XA0 Mode selector switch: Toggle switch design. Diagnostic buffer: The last 120 fault and interrupt events...? css/ted.css The CPU 417-4 features: Powerful processor: The CPU achieves command execution times as low as0.018 µs per binary instruction. 32 MB work memory (of which 16 MB each for program and data); faster work memory for sections

       

      • 公司名稱(chēng):上海朔川電氣設(shè)備有限公司
      • 聯(lián) 系 人:吉夢(mèng)琪
      • 地址:上海市金山區(qū)涇波路129號(hào)
      • 2840735331

       

      SIPLUS CPU 417-4

      • 訂貨數(shù)據(jù)
      •  
      • 附件
      •  
      • 產(chǎn)品信息
      •  
      • 組態(tài)工具

      跳轉(zhuǎn)到

      概述

      應(yīng)用

      設(shè)計(jì)

       

      技術(shù)規(guī)范

      概述

      強(qiáng)大的 SIMATIC S7-400 CPU

      • 適用于對(duì)性能要求很高的工廠
      • 帶兩個(gè) IF 模塊的插槽

      注:

      SIPLUS extreme 產(chǎn)品基于 SIMATIC 標(biāo)準(zhǔn)產(chǎn)品。此處列出的內(nèi)容來(lái)自相關(guān)的標(biāo)準(zhǔn)產(chǎn)品。添加了特定 SIPLUS extreme 信息。

      有關(guān) SIPLUS 的技術(shù)文檔,可訪問(wèn):
      http://www.siemens.de/siplus-extreme

      應(yīng)用

      The CPU 417-4 is the most powerful SIMATIC S7-400 CPU. The integral PROFIBUS DP interfaces permit direct connection to the PROFIBUS DP fieldbus as master or slave.

      Two further DP master systems can be connected via the IF 964-DP interface submodules.

      Note:
      Only the interface module 6ES7 964-2AA04-0AB0 can be used.

      設(shè)計(jì)

      CPU 417-4 的特性:

      • 強(qiáng)大的處理器:
        CPU 執(zhí)行每條二進(jìn)制指令時(shí)間僅為 0.018 µs。
      • 32 MB 工作存儲(chǔ)器(程序和數(shù)據(jù)各 16 MB);
        快速工作存儲(chǔ)器用于對(duì)于執(zhí)行十分重要的用戶(hù)程序部分。
      • 可靈活擴(kuò)展:
        zui多 262 144 點(diǎn)數(shù)字量輸入/輸出和 16 384點(diǎn)模擬量輸入/輸出
      • MPI 多點(diǎn)接口:
        通過(guò) MPI,可方便地將zui多 32 個(gè)站聯(lián)成網(wǎng)絡(luò),數(shù)據(jù)傳輸速率可高達(dá) 12 Mbit/s。該 CPU 可與通信總線 (C-bus) 和 MPI 的站之間建立zui多 44 個(gè)連接。
        注意:
        如果 PROFIBUS DP 接口和 MPI 接口同時(shí)運(yùn)行,那么只能將以下總線連接器連接到 MPI 接口:
        • 帶插口:6ES7 972-0BB42-0XA0
        • 不帶插口:6ES7 972-0BA42-0XA0
      • 模式選擇開(kāi)關(guān):
        撥位開(kāi)關(guān)設(shè)計(jì)。
      • 診斷緩沖區(qū):
        zui后的 120 個(gè)故障和中斷事件保存在一個(gè)環(huán)形緩沖器中,用于進(jìn)行診斷(可擴(kuò)展)。
      • 實(shí)時(shí)時(shí)鐘:
        CPU 的診斷報(bào)警帶有日期和時(shí)間標(biāo)記。
      • 存儲(chǔ)卡:
        用于擴(kuò)展內(nèi)置裝載存儲(chǔ)器。存儲(chǔ)在裝載存儲(chǔ)器中的信息包括 S7?400 參數(shù)數(shù)據(jù)以及程序,因此需要 2 倍的存儲(chǔ)空間。其結(jié)果是:
        • 內(nèi)置的裝載存儲(chǔ)器不能滿(mǎn)足大程序量的要求,因此需要存儲(chǔ)卡。
          可使用 RAM 和 FEPROM 卡(FEPROM 卡用于保持性存儲(chǔ))。
      • PROFIBUS DP 接口:
        通過(guò) PROFIBUS DP 主站接口,可以實(shí)現(xiàn)分布式自動(dòng)化組態(tài),從而提高了速度,便于使用。對(duì)用戶(hù)來(lái)說(shuō),分布式 I/O 單元可作為一個(gè)集中式單元來(lái)處理(相同的組態(tài)、編址和編程)。
        混合組態(tài):SIMATIC S5,SIMATIC S7 為 PROFIBUS 主站,符合 EN 50170 標(biāo)準(zhǔn)。
        注:
        當(dāng)同時(shí)使用 PROFIBUS DP 和 MPI 接口時(shí),只能將下列總線連接器連接到 MPI 接口:
        • 帶插口:6ES7 972-0BB42-0XA0
        • 不帶插口:6ES7 972-0BA42-0XA0
      • 兩個(gè)附加插槽:
        可用 IF 964-DP 接口子模塊連接兩個(gè)附加的 PROFIBUS DP主站系統(tǒng)。

      • Block protection: 
        a password concept also protects the user program from unauthorized access
      • Integrated HMI services: 
        The user only has to specify the source and destination of the data with HMI devices. The data are then transported cyclically and automatically by the system.
      • Integrated communication functions:
        • PG/OP communication
        • Global data communication
        • S7 standard communication
        • S7 communication

      Configurable Attributes

      The STEP 7 tool "Hardware configuration" can be used to program the properties and response of the S7-400 including the CPUs, e.g.

      • Multipoint interface MPI:
        • Definition of node addresses
        • Startup/cycle behavior
        • Stipulation of the maximum cycle time and communication load
      • Address allocation: 
        Addressing of I/O modules
      • Retentive area: 
        Definition of the number of retentive bit memories, counters, timers, data blocks, and clock memories
      • Size of the process image, local data
      • Length of the diagnostics buffer
      • Protection level: 
        Definition of access authorizations to program and data
      • System diagnostics: 
        Definition of the handling and scope of diagnostics messages
      • Timed interrupts: 
        Setting of periods
      • Configuring

      Reporting functions

      • Status and fault indicators: 
        LEDs indicate internal and external faults and operating modes such RUN, STOP, restart, test function, etc.
      • Test functions: 
        The PG can be used to display signal states in program execution, modify process tags irrespective of the user program, read out the contents of stack memories, run separate program steps and inhibit program components.
      • Information functions: 
        The PG can be used to provide the user with information about the memory capacity and operating mode of the CPU, and the current utilization of the working and load memories.

      技術(shù)規(guī)范

      Article number

      6AG1417-4XT07-7AB0

       

      SIPLUS S7-400 CPU 417-4 V7

      General information

       

      Product type designation

      CPU 417-4

      Hardware product version

      01

      Firmware version

      V7.0

      Engineering with

       

      • ● Programming package

      STEP 7 V5.4 or higher with HSP 261

      CiR – Configuration in RUN

       

      CiR synchronization time, basic load

      60 ms

      CiR synchronization time, time per I/O byte

      7 µs

      Supply voltage

       

      Rated value (DC)

       

      • ● 24 V DC

      No; Power supply via system power supply

      Input current

       

      from backplane bus 5 V DC, typ.

      1.3 A

      from backplane bus 5 V DC, max.

      1.6 A

      from backplane bus 24 V DC, max.

      600 mA; 150 mA per DP interface

      from interface 5 V DC, max.

      90 mA; At each DP interface

      Power loss

       

      Power loss, typ.

      6.5 W

      Power loss, max.

      8 W

      Memory

       

      Type of memory

      RAM

      Work memory

       

      • ● integrated

      32 Mbyte

      • ● integrated (for program)

      16 Mbyte

      • ● integrated (for data)

      16 Mbyte

      • ● expandable

      No

      Load memory

       

      • ● expandable FEPROM

      Yes; with Memory Card (FLASH)

      • ● expandable FEPROM, max.

      64 Mbyte

      • ● integrated RAM, max.

      1 Mbyte

      • ● expandable RAM

      Yes; with Memory Card (RAM)

      • ● expandable RAM, max.

      64 Mbyte

      Backup

       

      • ● present

      Yes

      • ● with battery

      Yes; all data

      • ● without battery

      No

      Battery

       

      Backup battery

       

      • ● Backup current, typ.

      225 µA; up to 40 °C

      • ● Backup current, max.

      1 275 µA

      • ● Backup time, max.

      See reference manual, module data, Chapter 3.3

      • ● Feeding of external backup voltage to CPU

      5 V DC to 15 V DC

      CPU processing times

       

      for bit operations, typ.

      7.5 ns

      for word operations, typ.

      7.5 ns

      for fixed point arithmetic, typ.

      7.5 ns

      for floating point arithmetic, typ.

      15 ns

      CPU-blocks

       

      DB

       

      • ● Number, max.

      16 000; Number range: 1 to 16000

      • ● Size, max.

      64 kbyte

      FB

       

      • ● Number, max.

      8 000; Number range: 0 to 7999

      • ● Size, max.

      64 kbyte

      FC

       

      • ● Number, max.

      8 000; Number range: 0 to 7999

      • ● Size, max.

      64 kbyte

      OB

       

      • ● Number, max.

      see instruction list

      • ● Size, max.

      64 kbyte

      • ● Number of free cycle OBs

      1; OB 1

      • ● Number of time alarm OBs

      8; OB 10-17

      • ● Number of delay alarm OBs

      4; OB 20-23

      • ● Number of cyclic interrupt OBs

      9; OB 30-38 (shortest cycle that can be set = 500 µs)

      • ● Number of process alarm OBs

      8; OB 40-47

      • ● Number of DPV1 alarm OBs

      3; OB 55-57

      • ● Number of isochronous mode OBs

      4; OB 61-64

      • ● Number of multicomputing OBs

      1; OB 60

      • ● Number of background OBs

      1; OB 90

      • ● Number of startup OBs

      3; OB 100-102

      • ● Number of asynchronous error OBs

      9; OB 80-88

      • ● Number of synchronous error OBs

      2; OB 121, 122

      Nesting depth

       

      • ● per priority class

      24

      • ● additional within an error OB

      2

      Counters, timers and their retentivity

       

      S7 counter

       

      • ● Number

      2 048

      Retentivity

       

      • — adjustable

      Yes

      • — lower limit

      0

      • — upper limit

      2 047

      • — preset

      Z 0 to Z 7

      Counting range

       

      • — lower limit

      0

      • — upper limit

      999

      IEC counter

       

      • ● Number

      Unlimited (limited only by RAM capacity)

      S7 times

       

      • ● Number

      2 048

      Retentivity

       

      • — adjustable

      Yes

      • — lower limit

      0

      • — upper limit

      2 047

      • — preset

      No times retentive

      Time range

       

      • — lower limit

      10 ms

      • — upper limit

      9 990 s

      IEC timer

       

      • ● present

      Yes

      • ● Type

      SFB

      • ● Number

      Unlimited (limited only by RAM capacity)

      Data areas and their retentivity

       

      retentive data area in total

      Total working and load memory (with backup battery)

      Flag

       

      • ● Number, max.

      16 kbyte; Size of bit memory address area

      • ● Retentivity available

      Yes

      • ● Retentivity preset

      MB 0 to MB 15

      • ● Number of clock memories

      8; in 1 memory byte

      Data blocks

       

      • ● Number, max.

      16 000; Number range: 1 to 16000

      • ● Size, max.

      64 kbyte

      Local data

       

      • ● adjustable, max.

      64 kbyte

      • ● preset

      32 kbyte

      Address area

       

      I/O address area

       

      • ● Inputs

      16 kbyte

      • ● Outputs

      16 kbyte

      of which distributed

       

      • — MPI/DP interface, inputs

      2 kbyte

      • — MPI/DP interface, outputs

      2 kbyte

      • — DP interface, inputs

      8 kbyte

      • — DP interface, outputs

      8 kbyte

      Process image

       

      • ● Inputs, adjustable

      16 kbyte

      • ● Outputs, adjustable

      16 kbyte

      • ● Inputs, default

      1 024 byte

      • ● Outputs, default

      1 024 byte

      • ● consistent data, max.

      244 byte

      • ● Access to consistent data in process image

      Yes

      Subprocess images

       

      • ● Number of subprocess images, max.

      15

      Digital channels

       

      • ● Inputs

      131 072

      • — of which central

      131 072

      • ● Outputs

      131 072

      • — of which central

      131 072

      Analog channels

       

      • ● Inputs

      8 192

      • — of which central

      8 192

      • ● Outputs

      8 192

      • — of which central

      8 192

      Hardware configuration

       

      Number of expansion units, max.

      21

      connectable OPs

      119

      Multicomputing

      Yes; 4 CPUs max. (with UR1 or UR2)

      Interface modules

       

      • ● Number of connectable IMs (total), max.

      6

      • ● Number of connectable IM 460s, max.

      6

      • ● Number of connectable IM 463s, max.

      4; IM 463-2

      Number of DP masters

       

      • ● integrated

      2

      • ● via CP

      10; CP 443-5 Extended

      • ● via IM 467

      4

      • ● Mixed mode IM + CP permitted

      No; IM 467 cannot be used jointly with CP 443-5 Ext. or CP 443-1 in PROFINET IO mode

      • ● via interface module

      2

      • ● Number of pluggable S5 modules (via adapter capsule in central device), max.

      6

      Number of IO Controllers

       

      • ● integrated

      0

      • ● via CP

      4; Max. 4 in the central controller; no mixed operation of different CP 443-1 types in PROFINET IO mode

      Number of operable FMs and CPs (recommended)

       

      • ● FM

      Limited by number of slots and number of connections

      • ● CP, PtP

      CP 440: Limited by number of slots; CP 441: limited by number of connections

      • ● PROFIBUS and Ethernet CPs

      14; Of which 10 CPs max. or IMs as DP master, 4 PROFINET controller maximum

      Slots

       

      • ● required slots

      2

      Time of day

       

      Clock

       

      • ● Hardware clock (real-time)

      Yes

      • ● retentive and synchronizable

      Yes

      • ● Resolution

      1 ms

      • ● Deviation per day (buffered), max.

      1.7 s; Power off

      • ● Deviation per day (unbuffered), max.

      8.6 s; For power On

      Operating hours counter

       

      • ● Number

      16

      • ● Number/Number range

      0 to 15

      • ● Range of values

      SFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 - 1 hours

      • ● Granularity

      1 hour

      • ● retentive

      Yes

      Clock synchronization

       

      • ● supported

      Yes

      • ● to MPI, master

      Yes

      • ● to MPI, slave

      Yes

      • ● to DP, master

      Yes

      • ● to DP, slave

      Yes

      • ● in AS, master

      Yes

      • ● in AS, slave

      Yes

      • ● on Ethernet via NTP

      No; Via CP

      • ● to IF 964 DP

      Yes

      Time difference in system when synchronizing via

       

      • ● MPI, max.

      200 ms

      Interfaces

       

      Interfaces/bus type

      1 x MPI/PROFIBUS DP, 1 x PROFIBUS DP, 2 x PROFIBUS DP (optionally pluggable)

      Number of RS 485 interfaces

      2; Combined MPI / PROFIBUS DP and PROFIBUS DP

      Number of other interfaces

      2; PROFIBUS DP with IF 964-DP (plug-in option; MLFB: 6ES7964-2AA04-0AB0)

      1. Interface

       

      Interface type

      Integrated

      Physics

      RS 485 / PROFIBUS + MPI

      Isolated

      Yes

      Power supply to interface (15 to 30 V DC), max.

      150 mA

      Number of connection resources

      MPI: 44, DP: 32

      Functionality

       

      • ● MPI

      Yes

      • ● PROFIBUS DP master

      Yes

      • ● PROFIBUS DP slave

      Yes

      MPI

       

      • ● Number of connections

      44; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1

      • ● Transmission rate, max.

      12 Mbit/s

      Services

       

      • — PG/OP communication

      Yes

      • — Routing

      Yes

      • — Global data communication

      Yes

      • — S7 basic communication

      Yes

      • — S7 communication

      Yes

      • — S7 communication, as client

      Yes

      • — S7 communication, as server

      Yes

      DP master

       

      • ● Number of connections, max.

      32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1

      • ● Transmission rate, max.

      12 Mbit/s

      • ● Number of DP slaves, max.

      32

      Services

       

      • — PG/OP communication

      Yes

      • — Routing

      Yes; S7 routing

      • — Global data communication

      No

      • — S7 basic communication

      Yes

      • — S7 communication

      Yes

      • — S7 communication, as client

      Yes

      • — S7 communication, as server

      Yes

      • — Equidistance

      Yes

      • — Isochronous mode

      Yes

      • — SYNC/FREEZE

      Yes

      • — Activation/deactivation of DP slaves

      Yes

      • — Direct data exchange (slave-to-slave communication)

      Yes

      • — DPV1

      Yes

      Address area

       

      • — Inputs, max.

      2 kbyte

      • — Outputs, max.

      2 kbyte

      User data per DP slave

       

      • — User data per DP slave, max.

      244 byte

      • — Inputs, max.

      244 byte

      • — Outputs, max.

      244 byte

      • — Slots, max.

      244

      • — per slot, max.

      128 byte

      DP slave

       

      • ● Number of connections

      32

      • ● GSD file

      http://support.automation.siemens.com/WW/view/en/113652

      • ● Transmission rate, max.

      12 Mbit/s

      • ● automatic baud rate search

      No

      • ● Address area, max.

      32; Virtual slots

      • ● User data per address area, max.

      32 byte

      • — of which consistent, max.

      32 byte

      Services

       

      • — PG/OP communication

      Yes; with interface active

      • — S7 routing

      Yes; with interface active

      • — Global data communication

      No

      • — S7 basic communication

      No

      • — S7 communication

      Yes

      • — S7 communication, as client

      Yes

      • — S7 communication, as server

      Yes

      • — Direct data exchange (slave-to-slave communication)

      No

      • — DPV1

      No

      Transfer memory

       

      • — Inputs

      244 byte

      • — Outputs

      244 byte

      2. Interface

       

      Interface type

      Integrated

      Physics

      RS 485 / PROFIBUS

      Isolated

      Yes

      Power supply to interface (15 to 30 V DC), max.

      150 mA

      Number of connection resources

      32

      Functionality

       

      • ● PROFIBUS DP master

      Yes

      • ● PROFIBUS DP slave

      Yes

      DP master

       

      • ● Number of connections, max.

      32

      • ● Transmission rate, max.

      12 Mbit/s

      • ● Number of DP slaves, max.

      125

      Services

       

      • — PG/OP communication

      Yes

      • — Routing

      Yes; S7 routing

      • — Global data communication

      No

      • — S7 basic communication

      Yes

      • — S7 communication

      Yes

      • — S7 communication, as client

      Yes

      • — S7 communication, as server

      Yes

      • — Equidistance

      Yes

      • — Isochronous mode

      Yes

      • — SYNC/FREEZE

      Yes

      • — Activation/deactivation of DP slaves

      Yes

      • — Direct data exchange (slave-to-slave communication)

      Yes

      • — DPV1

      Yes

      Address area

       

      • — Inputs, max.

      8 kbyte

      • — Outputs, max.

      8 kbyte

      User data per DP slave

       

      • — User data per DP slave, max.

      244 byte

      • — Inputs, max.

      244 byte

      • — Outputs, max.

      244 byte

      • — Slots, max.

      244

      • — per slot, max.

      128 byte

      DP slave

       

      • ● Number of connections

      32

      • ● GSD file

      http://support.automation.siemens.com/WW/view/en/113652

      • ● Transmission rate, max.

      12 Mbit/s

      • ● Address area, max.

      32

      • ● User data per address area, max.

      32 byte

      • — of which consistent, max.

      32 byte

      Services

       

      • — Routing

      Yes; with interface active

      Transfer memory

       

      • — Inputs

      244 byte

      • — Outputs

      244 byte

      3. Interface

       

      Interface type

      Pluggable interface module (IF), technical data as for 2nd interface

      Plug-in interface modules

      IF 964-DP (MLFB: 6ES7964-2AA04-0AB0)

      Physics

      RS 485 / PROFIBUS

      Isolated

      Yes

      Power supply to interface (15 to 30 V DC), max.

      150 mA

      automatic detection of transmission rate

      No

      Number of connection resources

      32

      Functionality

       

      • ● MPI

      No

      • ● PROFIBUS DP master

      Yes

      • ● PROFIBUS DP slave

      Yes

      DP master

       

      Services

       

      • — PG/OP communication

      Yes

      • — Routing

      Yes; S7 routing

      • — Global data communication

      No

      • — S7 basic communication

      Yes

      • — S7 communication

      Yes

      • — S7 communication, as client

      Yes

      • — S7 communication, as server

      Yes

      • — Equidistance

      Yes

      • — Isochronous mode

      Yes

      • — SYNC/FREEZE

      Yes

      • — Activation/deactivation of DP slaves

      Yes

      • — Direct data exchange (slave-to-slave communication)

      Yes

      • — DPV0

      Yes

      • — DPV1

      Yes

      Address area

       

      • — Inputs, max.

      8 kbyte

      • — Outputs, max.

      8 kbyte

      User data per DP slave

       

      • — User data per DP slave, max.

      244 byte

      • — Inputs, max.

      244 byte

      • — Outputs, max.

      244 byte

      • — Slots, max.

      244

      • — per slot, max.

      128 byte

      DP slave

       

      • ● Number of connections

      32

      • ● GSD file

      http://support.automation.siemens.com/WW/view/en/113652

      • ● Transmission rate, max.

      12 Mbit/s

      • ● Address area, max.

      32

      • ● User data per address area, max.

      32 byte

      • — of which consistent, max.

      32 byte

      Services

       

      • — PG/OP communication

      Yes

      • — S7 routing

      Yes; with interface active

      • — Global data communication

      No

      • — S7 basic communication

      No

      • — S7 communication

      Yes

      • — S7 communication, as client

      Yes

      • — S7 communication, as server

      Yes

      • — Direct data exchange (slave-to-slave communication)

      No

      • — DPV1

      No

      Transfer memory

       

      • — Inputs

      244 byte

      • — Outputs

      244 byte

      4. Interface

       

      Interface type

      Pluggable interface module (IF), technical data as for 2nd interface

      Plug-in interface modules

      IF 964-DP (MLFB: 6ES7964-2AA04-0AB0)

      Open IE communication

       

      • ● ISO-on-TCP (RFC1006)

      Via CP 443-1 and loadable FB

      • — Data length, max.

      1452 bytes via CP 443-1 Adv.

      Isochronous mode

       

      Isochronous operation (application synchronized up to terminal)

      Yes; For PROFIBUS only

      Equidistance

      Yes

      Number of DP masters with isochronous mode

      4

      User data per isochronous slave, max.

      244 byte

      shortest clock pulse

      1 ms; 0.5 ms without use of SFC 126, 127

      max. cycle

      32 ms

      Communication functions

       

      PG/OP communication

      Yes

      • ● Number of connectable OPs without message processing

      119

      • ● Number of connectable OPs with message processing

      119; When using Alarm_S/SQ and Alarm_D/DQ

      Data record routing

      Yes

      Global data communication

       

      • ● supported

      Yes

      • ● Number of GD loops, max.

      16

      • ● Number of GD packets, transmitter, max.

      16

      • ● Number of GD packets, receiver, max.

      32

      • ● Size of GD packets, max.

      54 byte

      • ● Size of GD packet (of which consistent), max.

      1 variable

      S7 basic communication

       

      • ● supported

      Yes

      • ● User data per job, max.

      76 byte

      • ● User data per job (of which consistent), max.

      1 variable

      S7 communication

       

      • ● supported

      Yes

      • ● as server

      Yes

      • ● as client

      Yes

      • ● User data per job, max.

      64 kbyte

      • ● User data per job (of which consistent), max.

      462 byte; 1 variable

      S5 compatible communication

       

      • ● supported

      Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5

      • ● User data per job, max.

      8 kbyte

      • ● User data per job (of which consistent), max.

      240 byte

      • ● Number of simultaneous AG-SEND/AG-RECV orders per CPU, max.

      64/64

      Standard communication (FMS)

       

      • ● supported

      Yes; Via CP and loadable FB

      Web server

       

      • ● supported

      No

      Number of connections

       

      • ● overall

      120

      • ● usable for PG communication

      119

      • — reserved for PG communication

      1

      • — adjustable for PG communication, max.

      0

      • ● usable for OP communication

      119

      • — reserved for OP communication

      1

      • — adjustable for OP communication, max.

      0

      • ● usable for S7 basic communication

      118

      • — reserved for S7 basic communication

      0

      • — adjustable for S7 basic communication, max.

      0

      • ● usable for S7 communication

      118

      • — reserved for S7 communication

      0

      • — adjustable for S7 communication, max.

      0

      • ● usable for routing

      59

      • — reserved for routing

      0

      • — adjustable for routing, max.

      0

      S7 message functions

       

      Number of login stations for message functions, max.

      119; Max. 119 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 16 with Alarm, Alarm_8, Alarm_8P, Notify and Notify_8 (e.g. WinCC)

      Symbol-related messages

      Yes

      SCAN procedure

      Yes

      Block related messages

      Yes

      Process diagnostic messages

      Yes

      simultaneously active Alarm-S blocks, max.

      1 000; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks

      Alarm 8-blocks

      Yes

      • ● Number of instances for alarm 8 and S7 communication blocks, max.

      10 000

      • ● preset, max.

      1 200

      Process control messages

      Yes

      Number of archives that can log on simultaneously (SFB 37 AR_SEND)

      64

      Number of messages

       

      • ● overall, max.

      1 024

      • ● in 100 ms grid, max.

      128

      • ● in 500 ms grid, max.

      512

      • ● in 1000 ms grid, max.

      1 024

      Number of additional values

       

      • ● with 100 ms grid, max.

      1

      • ● with 500, 1000 ms grid, max.

      10

      Test commissioning functions

       

      Status block

      Yes; Up to 16 simultaneously

      Single step

      Yes

      Number of breakpoints

      16

      Status/control

       

      • ● Status/control variable

      Yes; Up to 16 variable tables

      • ● Variables

      Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters

      • ● Number of variables, max.

      70; Status/control

      Forcing

       

      • ● Forcing

      Yes

      • ● Forcing, variables

      Inputs, outputs, bit memories, peripheral inputs, peripheral outputs

      • ● Number of variables, max.

      512

      Diagnostic buffer

       

      • ● present

      Yes

      • ● Number of entries, max.

      3 200

      • — adjustable

      Yes

      • — preset

      120

      Service data

       

      • ● can be read out

      Yes

      Standards, approvals, certificates

       

      CE mark

      Yes

      EAC (formerly Gost-R)

      Yes

      Ambient conditions

       

      Ambient temperature during operation

       

      • ● min.

      -25 °C; = Tmin

      • ● max.

      70 °C; = Tmax

      Extended ambient conditions

       

      • ● relative to ambient temperature-atmospheric pressure-installation altitude

      Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)

      Relative humidity

       

      • — With condensation, tested in accordance with IEC 60068-2-38, max.

      100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation

      Resistance

       

      • — against biologically active substances / conformity with EN 60721-3-3

      Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

      • — against chemically active substances / conformity with EN 60721-3-3

      Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

      • — against mechanically active substances / conformity with EN 60721-3-3

      Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

      Configuration

       

      Configuration software

       

      • ● STEP 7

      Yes

      Programming

       

      • ● Command set

      see instruction list

      • ● Nesting levels

      7

      • ● Access to consistent data in process image

      Yes

      • ● System functions (SFC)

      see instruction list

      • ● System function blocks (SFB)

      see instruction list

      Programming language

       

      • — LAD

      Yes

      • — FBD

      Yes

      • — STL

      Yes

      • — SCL

      Yes

      • — CFC

      Yes

      • — GRAPH

      Yes

      • — HiGraph®

      Yes

      Number of simultaneously active SFCs

       

      • — DPSYC_FR

      2; SFC 11; per interface

      • — D_ACT_DP

      8; SFC 12; per interface

      • — RD_REC

      8; SFC 59; per interface

      • — WR_REC

      8; SFC 58; per interface

      • — WR_PARM

      8; SFC 55; per interface

      • — PARM_MOD

      1; SFC 57; per interface

      • — WR_DPARM

      2; SFC 56; per interface

      • — DPNRM_DG

      8; SFC 13; per interface

      • — RDSYSST

      8; SFC 51

      • — DP_TOPOL

      1; SFC 103; per interface

      Number of simultaneously active SFBs

       

      • — RDREC

      8; SFB 52; per interface, but not more than 32 across all external interfaces

      • — WRREC

      8; SFB 53; per interface, but not more than 32 across all external interfaces

      Know-how protection

       

      • ● User program protection/password protection

      Yes

      • ● Block encryption

      Yes; With S7 block Privacy

      Dimensions

       

      Width

      50 mm

      Height

      290 mm

      Depth

      219 mm

      Weights

       

      Weight, approx.

      900 g

       

       

       